Troubleshoong Not Feeding Tape
If the power indicator lamp is illuminated but the motor does not start check the following:
Interlock Circuit
Top cover open
Verify the top cover is fully closed and seated properly
Magnet missing
Verify that the small magnet located in the top cover is present. It should be found opposite of the
magnet reed switch (1/2” diameter circular disk, or 1”X1/4” black rectangular switch depending on
producon year) in the le side of the from when the cover is completely closed. Only one magnet will
be in either locaon. (Figure 1)
Interlock switch circuit not plugged in
Verify that the interlock reed switch is plugged into the controller board at the connector marked
“interlock.