10
Rev 9 2022
Troubleshoong Not Feeding Tape
If the power indicator lamp is illuminated but the motor does not start check the following:
• Interlock Circuit
◊ Top cover open
▪ Verify the top cover is fully closed and seated properly
◊ Magnet missing
▪ Verify that the small magnet located in the top cover is present. It should be found opposite of the
magnet reed switch (1/2” diameter circular disk, or 1”X1/4” black rectangular switch depending on
producon year) in the le side of the from when the cover is completely closed. Only one magnet will
be in either locaon. (Figure 1)
◊ Interlock switch circuit not plugged in
▪ Verify that the interlock reed switch is plugged into the controller board at the connector marked
“interlock.”
Figure 1