30
Rev 9 2022
Maintenance & Repair Motor Chain Adjustment
Tools Needed
• 3/8” Wrench
• Philips head screwdriver
Procedure
1. Unplug Machine
2. Remove the water bole, and tank assembly
3. Remove right side cover (5 Philips screws)
4. Loosen the 2 3/8” nuts holding the motor to the
bracket (do not remove the nuts completely)
(Figure 1)
5. Slide the motor toward the back of the machine
unl there is no more slack in the chain (Figure 2)
6. Tighten the 2 3/8” nuts locking the motor in place
7. Replace the right cover (5 Philips screws)
8. Replace water tank, brushes, and water bole
Figure 1