Other functions Step 1 Step 2 Step 3 Step 4 Step 5
Set door release time Enter progr. mode Press A28 Enter no of seconds (01-99)
Set door held warning time Enter progr. mode Press A29 Enter no of seconds
(01-99)
Buzzer on/off Enter progr. mode Press A65 1 = Buzzer on
0 = Buzzer off
Calculated PIN Enter progr. mode Press A24 Enter a 4-digit calculation factor
Card reading parameters Enter progr. mode Press A97 Enter start position
(01-40)
Enter no of positions to
be read (1-8)
Change password Enter progr. mode Press A27 Enter new password
(6 digits)
Enter new password
once again
Erase memory Open BC615 Make link 1 and
remove
Enter 112186 on the keypad Enter 112186 on the
keypad once again