BM3 Installation & User Manual 27
ENG
Function Step 1 Step 2 Step 3 Step 4 Step 5
Possibility to call
into Bewacom
Press
A66
Enter code (four digits) Enter the
code once
again
Press B to
exit.
Hotline off/off Press
A67
0 = OFF
1 = ON
Press B to
exit.
Change maxnumber
of digits in exten-
sion
Press
A92
Enter number of digits
(01-99)
Erase memory Open
Bewa-
com
Press SW1 on the circuit
board
Enter
112186 on
the keypad
Enter 112186
once again

Table of Contents