EasyManua.ls Logo

Bewator BM3 - Troubleshooting Common Issues

Bewator BM3
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 BM3 Installation & User Manual
ENG
Troubleshooting
Problem Possible cause Action
Nothing hap-
pens when a
code is entered.
The code is
timed.
Check connect-
ed time clock.
Unable to enter
programming
mode. Red LED
lit after two
trials.
Wrong pass-
word.
Determine the
correct pass-
word.
Green LED lit
following an
accepted code,
but the door
does not open.
Lock fault. Check cable
between door
telephone and
lock. Change
locks.
Link between
block nos 1 and
4 in Bewacom is
missing.
Attach link.
The B button
is pressed, but
no dial tone is
heard.
Faulty connec-
tion between
Bewacom and
telephone sys-
tem.
Check connec-
tions and cable.
The door tele-
phone extension
is not analogue.
Check the tel-
ephone system.
Connect an
ordinary push-
button tel-
ephone instead
of Bewacom.

Table of Contents

Related product manuals