7 Operation and Control BigRep STUDIO
72
XY-Off sets for extruder T1
The XY calibration prepares the machine for dual extrusion. The calibration must
be done by the user a er replacing the extruder or hotend and a er any relocation
of the printer. It can also be done if a wrong o set between the nozzles is recog-
nized while using dual extrusion.
› Go to [support.bigrep.com] and download the XY o set calibration files
› Step 1: Calculate the o sets with a resolution of 0.5 mm
– Print the G-code
Step1_XY_STUDIO_Gcode which has a resolution
of 0.5 mm.
– When the print is finished, do not take it o the bed!
– Identify the o sets. The shapes printed with Extruders T0 and T1 should
just match in one point. Identify the point in which they match and
write down the o set using the template below. (Fig. 7-3)
– Go to the Advanced Menu, update the o sets and save.
Fig. 7-3 : Template – on this example: X off set = +0,5 mm, Y off set = 0 mm
Fig. 7-4: Off set adjustment