Turn the output off by pressing the OUTPUT ON button (make sure the backlight is off).
Set the voltage and current to 0 V and 0 Amps.
Turn the output on by pressing the OUTPUT ON button (make sure the backlight is on), now, current
and voltage are set to zero.
Run the sequence: Press the Menu button (Shift function) + Toggle button.
Turn the output off by pressing the OUTPUT ON button (make sure the backlight is off), sequence will
continue running, but there will be no output.
Turn the sequence off by pressing the Menu button (Shift function) +Toggle button.
Example 1: Pulse waveform
1. Press PRESET A button and set 10 V using the Voltage knob and using the current knob
enter 1 Amp. Following this procedure also configure PRESET B with values 5 V and 1 Amp.
2. Press and hold the Menu button (~4 seconds).
3. Use the Voltage knob to find the dudt Set then press the Voltage knob to enter the menu.
4. Use the Voltage knob to navigate to the FunA screen and enter a time of 3 seconds (003) by
rotating the current knob and press the Voltage knob to enter this value.
5. Rotate the Voltage knob to navigate to the FUNB screen and adjust the time following the
procedure in step #4, but this time set the FUNB value to 003.
6. Rotate the Voltage to navigate to the FUNC screen and adjust the time following the
procedure in step #4, but this time set the FUNC value to 000 since this preset will not be
used.
7. In the same menu, dudt Set, use the Voltage knob to set the transition time from preset A
to preset B y setting A_b_ to 0000 and b_A_ also 0000.
8. Also, set the run to A_b to indicate a transition from PRESET A to PRESET B.
9. Set rUNt to 0000 which means “cycle indefinitely “.
10. To generate the waveform, push the “Shift” key and then press the “Output on” button.
The waveform will repeat cyclically if rUNt 0000 is set to 0000 or according to number of
cycles entered. The output will show a pulse waveform with 3 seconds at 10 V and 1
second at 5 V.
11. Press the OUTPUT ON button to turn the output off (backlight should be off, too).
12. To stop the cycle running, push the “Shift” key and then press “Output on” button.
w ww . . co m
information@itm.com1.800.561.8187