Troubleshooting
Error Code 24
Drain blocked. The steam generator could not be emptied during flushing. The
level sensor reports high water level when the generator is emptied.
1 Go to the test menu to see which
information the computer displays.
2 Check that there is no scale in the
steam generator and no foreign
objects in the empty pump. The
empty pump may be broken. Check if
the generator can be emptied now.
3 Clean and descale the water level
tube, and test it using the test menu,
and then check if the generator can
be emptied now.
Error Code 25
The ClimaOptima function has not been calibrated.
Go to the service menu to calibrate.
process. The oven must be
44 SERVICE MANUAL
Tube may have debris in front
of the water level sensor
giving a false reading of full
when it is really empty.