Appendix E: Gas Pressure-switch Adjustment
Pressure-switch table OFF->ON
Oven types
RPM
Tolerance
1.06 = 61
3100
±100
1.10 = 101
2300
±100
1.20
2300
±100
2.06 = 62
2800
±100
2.10 = 102
2300
±100
2.20 = 202
2300
±100
9. If the registered value is lower than the value in the table, you have to adjust
the pressure switch clockwise. ½ turn adjusts approximately 150 RPM.
10. If the registered value is higher than the value in the table, you have to adjust
the pressure switch counter-clockwise. ½ turn adjusts approximately 150 RPM.
11. When you have completed the adjustment, turn the controller OFF and ON.
12. Turn on the gas inlet.