Circuit diagram of percent reference value channel
Repetition frequency
Divider 497
(PWM S2IND)
(PWM) S3IND
(PWM) S6IND
0
Motorpoti
Percentage-Motorpoti
down 73
analog
digital
MFI1
Change-over 1 75
Change-over 2 76
Fixed percentage 1 520
Operation mode 476
Reference percentage source
0
1
FP
0
1
MP
+
Absolute
Max. reference
percentage 519
Percentage limits
%
max
%
min
Start / Stop /
Selection of rotation
-1
0
Reference
percentage value
Start clockwise 68
Start anti-
clockwise 69
%
Ď‘
rel.
Multifunction
Operation mode 452
Percentage-Motorpoti
up 72
Max.
Min.
Fixed percentage
Fixed percentage 2 521
Fixed percentage 3 522
Fixed percentage 4 523
Reference
percentage value
229
160 Operating Instructions ACU 06/13