3 Installation
3.1 Quick start
The following steps allow you to use the AMAX panel 2000/AMAX panel 2000 EN with factory
default values. To become familiar with programming AMAX panel 2000/AMAX panel 2000 EN,
read the information in Section 3.3 Programming, page 14.
1. Connect auxiliary equipment.
2. After all wiring is complete, connect the AC plug pack and backup battery to the control
panel. The MAINS indicator lights signify AC mains supply is connected.
If any zone is unsealed when you power up the system, the corresponding zone indicator
is lit constantly.
Once you power up the panel, Date and Time has to be set.
All Faults and Tamper conditions have to be reset.
3. Enter the default user code (2580) + (98) and press [#] to enable the installer’s access.
4. Enter Date and Time. Refer to Section 3.1.1 Setting date and time, page 13.
5. Enter the default Installer Code (1234) + (958) and press [#]. Two beeps sound and the
STAY and AWAY indicators flash simultaneously to indicate that you have entered into
installer’s programming mode. Once you enter the installer’s programming mode, you are
automatically positioned at location 000, the first digit of IP address / Primary telephone
number for Receiver 1.
6. Enter the IP address/Primary telephone number for Receiver 1 and then the port.
Programming a 15 in the telephone number indicates the end of the dialing sequence.
7. Program any other required changes. Otherwise, factory default settings are used.
8. Enter command [9 6 0] and press [#] to store the programming data and exit from
installer’s programming mode, a beep sounds and the STAY and AWAY indicators are
deactivated. The system is returned to the disarmed state and is ready for use. Refer to
Section 3.3.3 Installer’s Programming Command, page 16
9. Enter the default user code (2580) and (6) and press [#] to reset the panel.

Table of Contents

Other manuals for Bosch AMAX panel 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch AMAX panel 2000 and is the answer not in the manual?

Bosch AMAX panel 2000 Specifications

General IconGeneral
BrandBosch
ModelAMAX panel 2000
CategorySecurity System
LanguageEnglish

Related product manuals