78 en | Programming sheets AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12 Installation Manual Bosch Sicherheitssysteme GmbH
10 Programming sheets
10.1 Receiver Programming
10.1.1 Receiver Parameters
IP address is programmed as 17 digits data code. Digit 1-12 is for receiver IP address,
digit 13~17 is for communication port.
The dot does not need to be programmed. The IP address is combined by 4 units, each unit
has 3 digits. If any unit is less than 3 digits, use 0 to fulfill the data in the higher bits. If the
port number is less than 5 digits, use 0 to fulfill the data in the higher bits.
Report Options Location Default
Telephone Number/IP Address and Port for Receiver 1 000-016 15
Subscriber ID Number for Receiver 1 017-022 000000
Transmission Format for Receiver 1(0=Not used, 1=Contact
ID, 2=CFSK, 3=Bosch Network)
023
1
EN=1
Anti-replay for Receiver 1
0=Disable,1=Enable
024 1
Acknowledge Wait Time for Receiver 1 (05 – 99 seconds) 025-026 05
Pulse Interval Time for Receiver 1(001 – 999 Minutes) 027-029 001
Telephone Number/IP Address and Port for Receiver 2 030-046 15
Subscriber ID Number for Receiver 2 047-052 000000
Transmission Format for Receiver 2(0=Not used, 1=Contact
ID, 2=CFSK, 3=Bosch Network)
053 1
Anti-replay for Receiver 2
0=Disable, 1=Enable
054 1
Acknowledge Wait Time for Receiver 2 (05 – 99 seconds) 055-056 05
Pulse Interval Time for Receiver 2(001 – 999 Minutes) 057-059 001
Telephone Number/IP Address and Port for Receiver 3 060-076 15
Subscriber ID Number for Receiver 3 077-082 000000
Transmission Format for Receiver 3
(0=Not used, 1=Contact ID, 2=CFSK, 3=Bosch Network)
083 1
Anti-replay for Receiver 3
0=Disable, 1=Enable
084 1
Acknowledge Wait Time for Receiver 3 (05 – 99 seconds) 085-086 05
Pulse Interval Time for Receiver 3 (001 – 999 Minutes) 087-089 001
Telephone Number/IP Address and Port for Receiver 4 090-106 15
Subscriber ID Number for Receiver 4 107-112 000000
Transmission Format for Receiver 4
(0=Not used, 1=Contact ID, 2=CFSK, 3=Bosch Network)
113 1
Anti-replay for Receiver 4
0=Disable, 1=Enable
114 1
Acknowledge Wait Time for Receiver 4 (05 – 99 seconds) 115-116 05
Pulse Interval Time for Receiver 4
(001 – 999 Minutes)
117-119 001