25.2 View Point Status
The View Point Status feature shows the status (normal, open, or
short) for all points in the areas in which you have authority.
Viewing point status:
1. Open the Main menu.
2. Use [NEXT] to go to the Status menu option, and press
[ENTER], or simply press [2].
3. Use [NEXT] to go to the View Point Status menu option, and
press [ENTER], or simply press [2].
4. The display shows the number of points in the system. Use
[PREV] or [NEXT] to scroll through the list of points and each
point’s status.
5. Press [ESC] to exit the menu.
150 en | B92x/B91x Status menu Control Panels
2015.01 | 02 | F.01U.307.371 Bosch Security Systems, Inc.

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories