EasyManuals Logo

Bosch B4512 Owner's Manual

Bosch B4512
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #191 background imageLoading...
Page #191 background image
28.3 Schedule (SKEDs)
A SKED is a function programmed to be performed automatically
at a scheduled time by your security system. You can change the
scheduled time for SKEDs, disable a SKED to prevent it from
automatically happening, or restart a previously disabled SKED.
Contact your security company to determine what SKEDs they
programmed for your system.
Selecting a SKED to change:
1. Open the Main menu.
2. Use [NEXT] to go to the Settings menu option, and press
[ENTER], or simply press [5].
3. Use [NEXT] to go to the Schedule menu option, and [ENTER],
or simply press [3].
4. Enter your passcode and press [ENTER].
5. Use [PREV] or [NEXT] to scroll through the list of SKEDs. The
keypad indicates whether a SKED is enabled, disabled, or not
yet programmed.
6. With the SKED you wish to enable showing, press [ENTER].
7. Continue to Enabling a disabled SKED or Disabling a enabled
SKED.
Control Panels B92x/B91x Settings menu | en 191
Bosch Security Systems, Inc. 2015.01 | 02 | F.01U.307.371

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories

Related product manuals