Settings
15
Control 8313 – 6720859552 (2017/03)
4.2 Advanced functions for heating circuits
You need the extended functions to change the factory defaults of your
heating circuit.
If the system has several heating circuits, the settings for each heating
circuit must be made separately.
Table 4 Advanced functions for heating circuits
4.3 Advanced functions for DHW
Table 5 Advanced functions for DHW
Extended function Explanation/Function Note
Party function Setting which specifies how long the heating system heats at the preset
room temperature in heating mode
The function is immediately active following
the input ( Chapter
5.5
, page
18
).
Pause function Setting that specifies how long the heating system only heats at the preset
room temperature in setback mode
The function is immediately active following
the input ( Chapter
5.6
, page
18
).
Holiday function Setting that specifies how long the heating system heats up to the preset
room temperature in setback mode.
The holiday period can be set via a year
calendar ( Chapter 5.4, page 17).
Circulation Adjustment Adjustment range Explanation Note
Operating mode
Circulation
DHW circulation
time program
On Setting the operating mode of the
DHW circulation pump
The DHW circulation pump runs
continuously.
The function depends on the
factory defaults which vary
according to the system.
( Chapter 5.8.1, page 18)
Auto The DHW circulation pump operates
independently of the heating
circuits according to the custom
time program at the intervals set
( Chapter 5.8.1, page 18).
Off The DHW circulation pump is not
activated. The DHW circulation
pump is switched on for the duration
of the once-only cylinder charging
operation via the Once-only cylinder
charging function.
Start-up frequency Start-up
frequency per
hour
On/Off Setting that specifies how often the
DHW circulation pump runs every
hour for 3 minutes.
You can reduce the operating
costs of the DHW circulation
pump by using intermittent
operation.
The function depends on the
factory defaults which vary
according to the system.
( Chapter 5.8.1, page 18)
Once on
Twice on
Three times on
Four times on
Five times on
Six times on
Continuous operation
Once-only cylinder
charging
Option of heating the DHW once,
although the system is in setback
mode.
( Chapter 5.8.2, page 19)

Table of Contents

Other manuals for Bosch Control 8313

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Control 8313 and is the answer not in the manual?

Bosch Control 8313 Specifications

General IconGeneral
BrandBosch
ModelControl 8313
CategoryControl Unit
LanguageEnglish

Related product manuals