EasyManua.ls Logo

Bosch Denoxtronic Set PC-LD - Cleaning; Calibration; Calibrating the Scale 0 986 610 838; Inspecting Weight 0 986 610 839

Bosch Denoxtronic Set PC-LD
168 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0 986 613 900, accessories and packaging
should be sorted for environmental-friendly
recycling.
Do not dispose 0 986 613 900 into
household waste.
Only for EC countries:
The 0 986 613 900 is subject to the Euro-
pean directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of 0 986 613 900 prevents
environmental pollution and possible
health hazards.
5.1 Change of location
If the 0 986 613 900 is passed on, all the documen-
tation included in the scope of delivery must be
handed over together with the unit.
The 0 986 613 900 is only ever to be transported in
the original or equivalent packaging.
5.2 Disposal and scrapping
5. Decommissioning
1 689 989 454 2019-08-01| Robert Bosch GmbH
Maintenance | 0 986 613 900 | 17 | en
6. Technical data
6.1 Dimensions and weights
Property Value / range
Dimensions (case, lying) H x W x D: 130 x 546 x 437mm
Weight: 7.2kg
6.2 Measurement functions
Measurement functions Measuring range Accuracy
Pressure (pressure gauge) –100kPa – +900kPa Class 1
(EN837-1)
Use a universal binding agent to absorb spilled
AdBlue. Dispose of the universal binding agent and
components in contact with AdBlue (e.g. filters) in
accordance with regional guidelines.
Dispose of pure liquid AdBlue in accordance with
regional guidelines.
i Outside of the Federal Republic of Germany, obser-
ve the applicable national regulations.
4.2 Cleaning
! Observe the safety instructions and cleanliness
rules pertaining to AdBlue.
i After the functional test has been performed, clean
the parts of the Denoxtronic setPC/LD used and the
dosing module. Surfaces wet with AdBlue must be
rinsed with plenty of warm water and then dried by
using compressed air. Otherwise, drying will result in
crystallization leading to corrosion and components
becoming unusable. This primarily affects connectors
and electronic components.
1. Fully drain the hydraulic lines, test pressure lines,
pressure gauge, measuring vessel and measuring
device. No residual AdBlue may remain in the parts.
2. Use a matching sealing plug to protect the electri-
cal connection before cleaning the dosing module.
3. Use plenty of warm water to rinse all the parts,
especially the pressure gauge.
4. Then, dry all the parts by means of compressed air
until completely dry.
5. To prevent contamination, place protective caps on
open connections.
4.3 Calibration
4.3.1 Calibrating the scale 0986610838
i The weight 0986610839 must be used to calibra-
te the scale.
1. Use <ON/TARE> to switch on the scale.
2. Press and hold <OFF> until the display shows CAL.
3. Release <OFF>. The display will show the value of
the required balance weight.
4. Place the balance weight 0986610839 on the
center of the plate.
5. The display will briefly show F and then the scale
will switch off.
6. Remove the balance weight 0986610839 from the
plate.
" The calibration will be complete, and the scale will
be ready for operation again.
i In case of a calibration error or incorrect balance
wight, E will appear on the display. Repeat the
calibration.
4.3.2 Inspecting weight 0986610839
Have the weight inspected by an approved inspection
office every 2 years.