EN | 22
Bosch Security Systems | 2006-05 | V2.0
Dinion IP | Installation Manual
• Use the left or right keys to move through options or to set parameters.
• When in a menu, quickly pressing the menu/select key twice restores the
selected item to its factory default.
• To close all menus at once from any menu, select the Exit item and hold down
the menu/select key until the menu display disappears.
Install menu
Install lens wizard submenu
Adjustment procedure DC-iris Lens
1. Unlock the back focus locking button.
2. Access the Lens Wizard menu.
3. Set Back Focus Now is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
Function Selection Description
Lens Wizard Select submenu Select to optimize camera lens combination
Network Select submenu Select to set the network IP address for the camera
(default address is 192.168.0.1)
Exit Exit the menu
Function Selection Description
Lens Type AUTO, MANUAL,
DCIRIS, VIDEO
In AUTO mode the camera auto detects the type of
lens used or force the camera into a mode.
Detected If the LENS TYPE detection is in AUTO, the
detected lens type is shown.
Set Back
Focus Now
Select to force lens to its maximum opening. After
focusing the lens the object of interest remains in
focus in bright and low light conditions.
Set LVL (Video iris lenses only). The level detector indicator
must be set to the center by adjusting the level
potentiometer on the lens, to obtain the best picture
performance.
Exit Return to the INSTALL menu