Adjustment procedure Manual-iris Lens
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
Adjustment procedure Video-iris Lens
1. Unlock the back focus locking button.
2. Access the Lens Wizard menu.
3. Set Back Focus Now is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Select Set LVL in the menu; the Level bar appears.
7. Point the camera at the scene it will be mostly viewing.
8. Adjust the level potentiometer located on the lens until the Level bar is in
the central position.
9. Exit the menu.
Note
The best performance with video iris lenses is obtained when the peak/
average potentiometer of the lens matches the peak/average balance
configuration setting.
Install IP address submenu
To operate the camera in your network, a network-valid IP address must be
assigned. The factory default IP address is 192.168.0.1
Function Selection Description
IP Address Enter an IP address for the camera. Use LEFT/
RIGHT to change position in the address, use UP/
DOWN to select the digit. Use SELECT to exit the
address edit screen.
Subnet Mask Enter the Subnet mask (default 255.255.255.0)
Gateway Enter a Gateway address.
Exit Return to the Install menu