2 Information about the appliance
• These controls are used to display device and
system information and to change the settings
shown.
• In connection with the IPM 2 module the
controls are an outdoor reset control for two
heating zones and DHW provision with time
programs:
– Central heating : Six weekly heating
programs with six switch points per day
are programmable (one program is active).
– Hot water : weekly DHW program with
six switch points per day.
• Options:
– Remote control FB 100 with IPM2 module
for expansion up to max. 4 heating zones.
– Module ISM 2 for solar water heating and
solar heating boost.
• The controls have a power reserve sufficient
for at least 6 hours of operation. If the
controls are without power for a period longer
than the power reserve, then the time and
date will be deleted. All other settings are
kept.
• Installation options:
– In the boiler with BUS-enabled Heatronic 3
– Wall-mounted with BUS link to boiler with
BUS-enabled Heatronic 3
2.1 Scope of delivery
Fig. 4 Scope of delivery
1 Controls top section
2 Base for wall-mounting
3 Slide cover
4 Installation and operating instructions
5 Outdoor temperature sensor with
mounting kit
The FW 200 can only be connected
to a boiler with BUS-enabled
Heatronic 3.