EasyManua.ls Logo

Bosch FWA 43 Series - Special Handling of Individual Measuring Processors; Updating the Cameras; Settings;Flash Writer; Special Instructions and Error Messages

Bosch FWA 43 Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 690 326 006 2008-8-25| Robert Bosch GmbH
en 42 | FWA 43xx / 44xx | Operating System-Software
Special handling of individual measuring 14.8.8
processors
This step is executed only if the pervious update 1.
of an individual measuring processor is missing or
sensor has not been obtained in case of version
check.
One tries to update the measuring processors in 2.
a special mode, which enables an update also in
case of missing or incorrect Firmware.
Please note that only the sensor to be updated 3.
should be connected to the cable: All others must be
unplugged.
If you do not want to update the individual sensor 4.
knowingly and thus they cannot be connected, you
can skip this step for the respective equipment.
Please do not forget to reconnect all sensor via cable 5.
after all related sensor are specially treated.
Updating the cameras14.8.9
The cameras shall be updated and the result shall be 1.
displayed.
At first, all the cameras 1 (front) and then all the 2.
cameras 2 (behind) of the connected sensor are
updated one after the other.
The step is executed only if the firmware file receives 3.
a current version as already existing or the version
check is deactivated.
Changes are not executed (Keystrokes, cable
i
plugged / unplugged or similar) in the connected
equipments, as long as data transfer takes place.
A continuous data transfer is signalised by flashing
all LEDs in the operation field of the sensor.
Check the connected equipment / result
A subsequent check of the equipment is carried out
and the result of the update is displayed.
Settings/FlashWriter14.8.10
The settings dialogue serves the following options
R
and setting options:
Option list "Language": Enables the language option 1.
for program user interface. If the program is running
for the first time, a screen page appears, in which
the language can also be selected.
Option "Version comparison not executed": By 2.
default a Firmwareupdate is executed only if the
versions of the Firmware-Images are updated
as Firmware equipment from the Firmware file.
Therefore a version comparison is executed at the
beginning, in order to be able to decide which
equipment can be updated. This version comparison
can be deactivated. In this case, the version check is
executed at the beginning of a program run, whose
result shall however not be taken into consideration
in case of active option. The option shall be reset at
the end of the program.
Option "Use other Firmware file": By default 3.
Firmware-Images are included in the FlashData.xml
file, it is in the same directory as of the program file
FlashWriter.exe. If this option is enabled, the file
displayed in the underlying text field shall be used.
Change in this option does not have any effect on 4.
the update process that has already started.
The option shall be reset at the end of the program; 5.
the selected Firmware file are saved.
Special instructions and error messages14.8.11
In error case, the screen page is displayed with
i
a corresponding message.

Table of Contents

Related product manuals