1 690 326 006 2008-8-25| Robert Bosch GmbH
Operating System-Software | FWA 43xx / 44xx | 49 en
Configuration setting Niveau.ini
The file Niveau.ini saves the COM-Port (COM 3 [de-
fault]). The measured values can be read in the main
program by an inclination measering device. The file
Niveau.ini saves the number to which the inclination
measering device is connected.
COM3 = Default
COM1 = assigned by a remote control recipient COM2 =
assigned through the measurement box
COM3 = free for inclinometer
COM4 = free
INI-file of the main program
[LanguageServer] ILSV = language server
Entry Legend
Address=localhost Address = Local hard disk
Port=1096 Port address for server inquiry
Tab. 10:
[CCDServer] CCD = measured data-server
Entry Legend
Address=localhost Address = Local hard disk
Port=1081 Port address for server inquiry
Tab. 11:
[DemoServer] Demo server
Entry Legend
Address=localhost Address = Local hard disk
Port=1082 Port address for server inquiry
Tab. 12:
[LicenceServer] Lizenz-Server
Entry Legend
Port=1085 Port address for server inquiry
Tab. 13:
[MeasurementSystemSetup] Einstellung Messsystem
Entry Legend
OutOfTolerance=600
Equipment out of tolerance =
600" =10’ angle minutes
Tab. 14:
Only relevant settings are mentioned. i
CCD server14.11.3
CCD serverFig. 16:
Tasks
Separate Program module
R
Server for main program R
Provision of real-time measured values (currently R
measured in the vehicle)
Start before the main program
R
In case of manual start, begin before the main R
program
Interface between the main program and the
R
charging station and/or the sensors.
The role is to execute measuring tasks, which are
transferred from the main program to the server via a
TCP/IP-connection. The CCD server translates these
measuring tasks into the measuring system-specific
commands, and transmits these to the sensor via the
serial interface (RS232) of the charging station. The
measured values and status information required by the
main program are generated from the result, and sent
to the main program once again via the TCP/IP .
Function
The CCD server is a separate program module.
R
The CCD server contains diagnostic functions and R
a dialogue to edit configuration settings.
Path/program file
C:\<program files>\FWA-CCD\WheelAligner\CCD
R
CCD.exe R
Program start
Auto Start-Group
R
File description
CCD.EXE - Executable program file
R
CCD.INI - Configuration settings of the CCD server R

Table of Contents