1 692 106 011 2019-03-26| Robert Bosch GmbH
56 | HTD 6xx / HTD 8xx | Checking / calibration en
3. Check the position of the spirit level in the light box. In
the event of deviation from the center position, per-
form any necessary adjustment with the screws on the
trolley.
4. Check the position of the spirit level on the calibration
device. In the event of deviation from the center positi-
on, perform any necessary adjustment with the screws
on the calibration device.
5. Switch on the laser on the calibration device or the
cross laser and align triangle to the vertical laser
line. Use the reference mark and tip of the triangle
for this purpose.
6. Using the adjustment wheel, set the inclination to
the "0" position.
7. Align the center of the lens with the laser cross and
the center of the test screen with the vertical laser
line.