1 692 106 011 2019-03-26| Robert Bosch GmbH
Service setting – HTD 8xx | HTD 6xx / HTD 8xx | 69 en
5. Service setting – HTD 8xx
i Various visualization and measurement function set-
tings can be made in the Service menu.
1. Click on "SERVICE" in the "OPTIONS" screen.
2. Enter PIN: 835231.
3. Select the desired option:
"The screen with the selected option is displayed.
Page 2 of the Service menu can be accessed with the
key.
i The test standard and the intended use can be set
on page 2.
Test standards
Test standard Description
Test ECE The device checks the head
-
lamps on the basis of the ECE
(European) standard
Test SAE The device checks the head
-
lamps on the basis of the SAE
(American) standard
Intended use
Intended use Device function
Real Use in the workshop
Demo Use for demonstration pur
-
poses
Lab Use for development