1 692 106 011 2019-03-26| Robert Bosch GmbH
64 | HTD 6xx / HTD 8xx | Checking / calibration en
1. If necessary, loosen the fastening screw for rotating
the vertical laser and rotate holder in such way that
both vertical laser lines are congruent.
1
Fig. 14: Fastening screw vertical laser
1 Fastening screw
2. Tighten the fastening screw of the vertical laser and
secure with locking varnish.
3. Check if the air bubble in the spirit level is still bet-
ween the lines.
If necessary, adjust the spirit level by rotating the
screws (Fig. 15/ 2) in such way that the air bubb-
le is located exactly between the markings.
1
22
Fig. 15: Adjusting the spirit level
1 Air bubble
2 Fastening screws / adjusting screws
4. Turn off cross laser
4.5 Calibrating the pendulum
1. Affix pendulum on a wall or another vertical surface
in such way that the line of the green vertical laser
runs through the center point of the pendulum sus-
pension.
i Instead of the vertical laser on the HTD 8xx, a self-
levelling cross laser can also be used.
Fig. 16: Attaching the pendulum