MY21P01 - 22_1.0_24.09.2020
52
Operation
6.3.2 Rechargeable battery
The battery is protected against deep discharge,
overcharging, overheating and short circuits by
Electronic Cell Protection (ECP). In the event of a
hazard, a protective circuit switches the battery off
automatically.
If a fault is detected in the battery, the LEDs flash
on the battery level indicator.
860, 861 Error in the power supply 1 Re-start the system.
2 Contact your specialist
dealer if the problem
persists.
870, 871,
880
883...
885
Communication error
1 Re-start the system.
2 Contact your specialist
dealer if the problem
persists.
889 Internal ABS error Contact your specialist
dealer.
890 ABS indicator lamp is
defective or missing; ABS
possibly not functioning
Contact your specialist
dealer.
No
screen
display
On-board computer
internal error
Re-start the drive system by
switching it on and off.
Code Description Method of resolution
Table 33: List of on-board computer error messages
Description Method of resolution
Code:
If the battery is outside its charging
temperature range, three LEDs will
flash on the battery level indicator.
1 Disconnect charger from
battery.
2 Leave battery to cool down.
3 Contact your specialist
dealer if the problem
persists.
Code:
If a fault is detected in the battery,
two LEDs flash on the battery level
indicator.
Contact your specialist
dealer.
Code:
No LEDs will flash if the charger is
defective and will not charge. One or
more LEDs will light up permanently,
depending on the battery level.
Contact your specialist
dealer.
Code:
No LEDs will light up if there is no
power.
1 Check all plug connections.
2 Check the contacts on the
battery for dirt. Clean the
contacts carefully if needed.
3 Contact your specialist
dealer if the problem
persists.
Table 34: List of battery error messages