Transport and storage | A15VSO/A15VLO series 12 25/60
The warranty will be voided if the requirements and storage conditions are not
observed or after expiration of the max. storage time (see Table 8).
How to proceed once the max. storage time elapses:
1 Check the entire axial piston unit for damage and corrosion prior to installation.
2 Perform atest run to check the axial piston unit for proper functioning and
leak-tightness.
3 If storage time exceeds 24 months, replace the shaft seal.
Once the max. storage time has elapsed, we recommend that you have the
axial piston unit checked by your BoschRexroth service partner.
For questions regarding repair and spare parts, contact your proper BoschRexroth
service partner or the service department of the manufacturer's plant of the
axial piston unit, see chapter 10.5 "Spare parts" on page 50
An uninstalled axial piston unit must be preserved with corrosion protection for the
duration of storage.
The following instructions only refer to axial piston units operated with
hydraulic uid on amineral oil basis. Other hydraulic uids require other
specic preservation measures. In such acase, consult your local contact
person; you can nd their contact information at
https://addresses.boschrexroth.com
BoschRexroth recommends the following procedure:
1 Clean the axial piston unit; see chapter 10.1 "Cleaning and care" on page 48
2 Drain the axial piston unit.
3 For storage times up to 12 months: Moisten the inside of the axial piston unit
with mineral oil and ll with approx. 100 ml mineral oil.
For storage times up to 24 months: Fill the axial piston unit with VCI corrosion
protection oil (20 ml).
The lling is carried out via the drain port T
1
, T
2
or T
3
, see chapter7.4
"Installing the axial piston unit", Fig. 10 to Fig. 12 on page37
4 Plug all ports so they are airtight
5 Coat unpainted areas of the axial piston unit with mineral oil or suitable,
easily removable corrosion protection, e.g.acid-free grease.
6 Pack the axial piston unit with desiccant in an airproof manner in corrosion
protection lm.
7 Store the axial piston unit in ashock-proof manner;
see "Requirement" on page 24 in this chapter.