BoschRexrothAG, RE 92802-01-B/2023-03-27
26/60 A15VSO/A15VLO series 12 | Installation
7 Installation
Prior to installation, the following documents should be to hand:
• Data sheet of the axial piston unit (contains the permissible technical data,
main dimensions and circuit diagrams of standard versions)
• Installation drawing for the axial piston unit (can be obtained from your contact
person at BoschRexroth, if required)
• Hydraulic circuit diagram for the axial piston unit (in the data sheet and on the
installation drawing)
• Hydraulic circuit diagram for the machine/system (available from the machine/system
manufacturer upon request)
• Order conrmation (contains the order-related technical data for your
axial piston unit)
7�1 Unpacking
The axial piston unit comes in apolyethylene material (PE) corrosion protection
lm.
CAUTION! Danger due to falling parts!
If the packaging is not opened correctly, parts may fall out and damage the parts
or even result in injury.
▶ Place the packaging on alevel underground with sufcient load-bearing capacity.
▶ Only open the packaging from the top.
▶ Remove the packaging from the axial piston unit.
▶ Check the axial piston unit for transport damage and completeness;
see chapter 4 "Scope of delivery" on page 18�
▶ Dispose of the packaging in accordance with the regulations in your country.
7�2 Installation conditions
The installation position and location of the axial piston unit essentially determine
how it is installed and commissioned (such as when lling and air bleeding the
axial piston unit).
▶ Fasten the axial piston unit so that the expected forces and torque can be
transferred without any danger. The machine/system manufacturer is responsible
for sizing the fastening elements.
▶ Observe the permissible radial forces on the drive shaft when driving with radial
loading (belt drives). If necessary, store the belt pulley separately.
▶ Make sure the axial piston unit is always lled with hydraulic uid during
commissioning and operation. Also do this also after relatively long standstill
periods, since the axial piston unit may drain out through the hydraulic lines.
▶ Direct the leakage in the housing area to the reservoir through the highest drain
port. Use aline size that matches the port.