RE 92802-01-B/2023-03-27, BoschRexrothAG
Removal and replacement | A15VSO/A15VLO series 12 51/60
11 Removal and replacement
111 Required tools
Removal can be performed using standard tools. No special tools are necessary.
112 Preparing for removal
1 Decommission the relevant system part as described in the instruction manual
for the machine or system.
Relieve pressure in the hydraulic system according to the instructions of the
machine or system manufacturer.
Make sure the relevant machine/system components are depressurized and
de-energized.
2 Secure the relevant system part against reactivation.
113 Performing the removal
Proceed as follows to remove the axial piston unit:
1 Make sure you have the appropriate tools and wear personal protective
equipment.
2 Allow the axial piston unit to cool down until it can be removed without danger.
3 For below-reservoir installation, before removing the axial piston unit, seal the
connection to the reservoir and/or drain the reservoir.
4 Place adrip tray under the axial piston unit to collect any hydraulic uid that
may leak.
5 Disconnect the lines and collect the escaping hydraulic uid in the drip tray.
6 Remove the axial piston unit. Use asuitable lifting device.
7 Completely drain the axial piston unit.
8 Plug all openings.
114 Preparing the components for storage or further use
Proceed as described in chapter 6.2 "Storing the axial piston unit" on page 24.