RE 92802-01-B/2023-03-27, BoschRexrothAG
Technical data | A15VSO/A15VLO series 12 57/60
Table 12: Axial piston unit malfunction table
Malfunction Possible cause Remedy
Excessively high temperature
of hydraulic uid and housing
Excessively high inlet temperature at the
axial piston unit
Machine/system manufacturer:
Inspect system, e.g.malfunction in the cooler,
insufcient hydraulic uid in the reservoir
Wrong setting and/or malfunction of the
pressure limitation and pressure control
valves (e.g.high-pressure relief valve,
pressure controller)
Optimize the adjustment of the pressure
limitation and pressure control valves of the
axial piston unit and the pressure safeguarding
in the hydraulic system
Contact BoschRexroth Service
Contact machine/system manufacturer
Axial piston unit worn Replace axial piston unit;
contact BoschRexroth Service
15 Technical data
The permissible technical data for your axial piston unit can be found on the
datasheet 92802�
The data sheet can be found in the Download Center:
www.boschrexroth.com/ics/ref/media/92802
Additional information can be found in the Rexroth store:
www.boschrexroth.com/p-A15VSO-1x
Order-related technical data for your axial piston unit can be found in the order
conrmation.