RE 92802-01-B/2023-03-27, BoschRexrothAG
Safety instructions | A15VSO/A15VLO series 12 11/60
2�6 Product-specic safety instructions
The following safety instructions apply to chapters 6 to 14.
WARNING
Danger due to excessive pressure!
Risk of death or injury, or property damage!
Improperly changing the factory pressure settings can result in apressure
increase beyond the permissible maximum pressure.
Operating the unit above the maximum permissible pressure can cause
components to burst and hydraulic uid to escape under high pressure.
▶ Changes to the factory settings may only be made by BoschRexroth
specialists.
▶ In addition, apressure relief valve is required in the hydraulic system
as back-up. If the axial piston unit is equipped with apressure cut-off
and/or pressure controller, this is not an adequate safeguard against pressure
overload.
Danger due to suspended loads!
Risk of death or injury, or property damage!
Improper transportation may cause the axial piston unit to fall down and lead to
injury, e.g.crushing or fracture, or damage to the product.
▶ Make sure that the load bearing capacity of the lifting device is sufcient to
safely bear the weight of the axial piston unit.
▶ Never step or grip under suspended loads.
▶ Ensure astabletransport position.
▶ Use your personal protective equipment (e.g.safety goggles, safety gloves,
suitableworking clothes, safety shoes).
▶ Use suitablelifting devices for transport.
▶ Observe the prescribed position of the lifting strap.
▶ Observe the national laws and regulations on occupational health and safety,
and transportation.
System/machine under pressure!
Risk of death or serious injury when working on unsecured machines/systems!
Property damage!
▶ Switch off the relevant machine/system part and secure it against reactivation
according to the parameters by the machine/system manufacturer.
▶ Ensure that all relevant components of the hydraulic system are depressurized.
For this purpose, observe the parameters indicated by the machine/system
manufacturer.
▶ Please note that the hydraulic system might still be pressurized even after
separation from the actual pressure supply.
▶ Do not disconnect any line connections, ports or components as long as the
hydraulic system is under pressure.