EasyManua.ls Logo

Bosch rexroth 12 Series - Page 27

Bosch rexroth 12 Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RE 92802-01-B/2023-03-27, BoschRexrothAG
Installation | A15VSO/A15VLO series 12 27/60
A check valve in the drain line is only permissible on acase-by-case basis
following consultation. Please consult your proper contact person at
BoschRexroth.
To prevent the transmission of structure-borne noise, use elastic elements
to decouple all connecting lines from all vibration-capable components
(e.g.reservoir, frame parts).
Make sure the suction, drain, and return lines ow into the reservoir below the
minimum uid level under all operating conditions. This will prevent air from
being drawn in and foam from forming.
When designing the reservoir, ensure that there is adequate distance between
the suction line and the drain line. We recommend using abafe (bafe plate)
between suction line and drain line. A bafe improves the air separation
ability as it gives the hydraulic uid more time for desorption. Apart from that,
thisprevents the heated return ow from being drawn directly back into the
suction line. The suction port must be supplied with air-free, calmed and cooled
hydraulic uid.
Make sure that aminimum suction pressure of 0.8bar absolute (without charge
pump) or 0.7bar absolute (with charge pump) absolute is present at port
"S"during operation and at cold start, in all installation positions and
installation locations for the axial piston pump, see Fig. 7. See data sheet for
other pressure values.
S
-0.2
0.8 abs.
1
2
3
0
0
1
2
-1
2
1
Fig 7: Suction pressure
1 Absolute pressure gauge
2 Standard pressure gauge (relative)
The suction conditions improve with installation below and inside the reservoir.
Make sure that the working environment at the installation site is completely
free of dust and foreign substances. The axial piston unit should be clean when
installed. Contamination of the hydraulic uid can considerably affect the
function and service life of the axial piston unit.
When using pump carriers with the installation position "drive shaft upward",
dirt can accumulate on the shaft seal, which can lead to leaks. Particularlyin
case of highly contaminated ambient conditions, any potentially present air bleed
bores in the pump carrier should be plugged in compliance with applicable
standards and safety regulations. Apart from that, regular checks and/or cleaning
is necessary. Observe the information in chapter10.1 "Cleaning and care"
on page48 and Table 11 "Inspection schedule" on page49

Table of Contents

Related product manuals