BoschRexrothAG, RE 92802-01-B/2023-03-27
44/60 A15VSO/A15VLO series 12 | Commissioning
You can nd details of the minimum requirements on hydraulic uids in
BoschRexroth data sheets 90220, 90221 and 90222. The titles of the data
sheets can be found in Table 1 "Required and supplementary documentation"
on page5.
BoschRexroth evaluates hydraulic uids on the basis of the Fluid Rating
according to datasheet90235. For hydraulic uids which have been positively
evaluated in the Fluid Rating, please refer to data sheet 90245 "BoschRexroth
uid rating list for Rexroth hydraulic components (pumps and motors)".
Selection of hydraulic uid shall make sure that the operating viscosity in the
operating temperature range is within the optimum range (ν
opt
; see selection
diagram in the data sheet 92802).
To ensure the functional reliability of the axial piston unit, cleanliness level
20/18/15 according to at least ISO 4406 is required for the hydraulic uid.
At ahydraulic uid viscosity of less than 10 mm²/s (e.g.due to high temperatures
during short-term operation) at the drain port, acleanliness level of at
least 19/17/14 according to ISO4406 is required. You can nd parameters
on the permissible and optimal viscosities and admissible temperatures in
datasheet 92802�
Proceed as follows to ll the axial piston unit:
1� Place adrip tray under the axial piston unit to collect any hydraulic uid that
may leak.
NOTICE! Contaminated hydraulic uid!
The cleanliness levels of commercial hydraulic uids are usually insufcient for the
requirements of our components.
▶ Use asuitable lter system to lter hydraulic uids during lling to minimize
solid particle contamination and water in the hydraulic system.
2� Fill and air bleed the axial piston unit via the appropriate ports; see chapter 7.3
"Installation position" on page 28. Also ll the hydraulic lines of the system.
NOTICE! Risk of property damage due to inadequate lubrication!
Product can be damaged or destroyed!
▶ When using ashut-off valve in the suction line, make sure that the drive of the
axial piston unit can only be started when the shut-off valves are open.
▶ Dimension ashut-off valve in the suction line so that no inadmissible pressure
drop occurs in the suction area when the shut-off valve is open.
3� If you use ashut-off valve in the suction line, only operate the axial piston unit
with opened shut-off valves.
4� Test the direction of rotation of the drive motor. To do this, run the drive motor
briey at the lowest rotational speed (inching). Make sure that the direction
of rotation of the axial piston unit agrees with the details of the name plate,
see chapter 5.3 "Product identication", Fig. 4: Name plate A15VSO on page 21.
Procedure