Description Symbol Unit XMQ*-WQ001 XMQ*-WQ002
Minimum distance on the top of
the device
4)
d
top
mm 80
Minimum distance on the bottom
of the device
5)
d
bot
mm 80
Horizontal spacing at the device
6)
d
hor
mm
0 (for devices of the ctrlX DRIVE product group in the DC bus
group (central supply))
1.5 (for devices of the ctrlX DRIVE product group outside of the
DC bus group (individual supply))
10 (for everything else (control cabinet wall, other devices, etc.))
Rated control voltage input
7)
U
N3
V 24
Rated control current input
8)
I
N3
A 12 14.3
Short circuit current rating SCCR A rms 42000
Rated input voltage, power
9)
U
LN_nom
V DC 254 ... 750
Rated input current
I
LN
A DC 64 DC 162
Required wire size in accordance
with NFPA 79 and UL 508 A (in‐
ternal wiring);
10)
A
LN
AWG
Axis 1: 8
Axis 2: 10
Axis 3: 14
Axis 4: 14
Axis 1: 4
Axis 2: 8
Axis 3: 10
Axis 4: 14
Field wiring material (material;
conductor temperature; class)
Cu; 75 °C; 1
Output voltage
U
out
V AC 0 ... 500
Output current
I
out
A
Axis 1: AC 27
Axis 2: AC 18
Axis 3: AC 6.7
Axis 4: AC 3.3
Axis 1: AC 67
Axis 2: AC 35
Axis 3: AC 18
Axis 4: AC 3.3
Output frequency range
11)
f
out
Hz 0 ... 1600
1) 2) 3) Housing dimensions
4) 5) 6) See fig. "Air intake and air outlet at device"
7) Comply with supply voltage for motor holding brake;
The following power supply unit has to be used in the scope of
CSA/UL: ● UL508-certified ● output voltage: DC 24V ● output
current: ≤ 31 A; for power supply units with output current >
31 A: install fuses in accordance with UL248
8) See information on "Rated power consumption control voltage
input at U
N3
"
9) Mains input L1, L2, L3; For use on a solidly grounded wye
source only.
10) Copper wire; PVC-insulation (conductor temperature 75 °C;
T
a
≤ 40 °C) in accordance with NFPA 79 chapter 12 and
UL 508A chapter 28
11) Depending on switching frequency which was set in parameter
P‑0‑0001
Tab. 2-7: UL ratings and dimensions
ctrlX DRIVE Drive Controllers, Supply Units 15/43
Ratings and dimensions
R911392530_Edition 02 Bosch Rexroth AG