Description Symbol Unit
XMD*-
W0606
XMD*-
W1010
XMD*-
W1616
XMD*-
W2323
XMD*-
W5454
XMD*-
W7070
Rated control voltage input
7)
U
N3
V 24
Rated control current input
8)
I
N3
A 5.3 6.7
Short circuit current rating SCCR A rms 42000
Rated input voltage, power
9)
U
LN_nom
V DC 254 ... 750
Rated input current
I
LN
A DC 4.9 DC 8.1 DC 12.9 DC 18.8 DC 47.6 DC 61.7
Field wiring material (material;
conductor temperature; class)
Cu; 75 °C; 1
Output voltage
U
out
V AC 0 ... 500
Output current
I
out
A
Axis 1:
AC 2
Axis 2:
AC 2
Axis 1:
AC 3.3
Axis 2:
AC 3.3
Axis 1:
AC 5.3
Axis 2:
AC 5.3
Axis 1:
AC 7.7
Axis 2:
AC 7.7
Axis 1:
AC 27
Axis 2:
AC 27
Axis 1:
AC 35
Axis 2:
AC 35
Output frequency range
10)
f
out
Hz 0 ... 800 0 ... 1600
1) 2) 3) Housing dimensions
4) 5) 6) See fig. "Air intake and air outlet at device"
7) Comply with supply voltage for motor holding brake;
The following power supply unit has to be used in the scope of
CSA/UL: ● UL508-certified ● output voltage: DC 24V ● output
current: ≤ 31 A; for power supply units with output current >
31 A: install fuses in accordance with UL248
8) See information on "Rated power consumption control voltage
input at U
N3
"
9) Mains input L1, L2, L3; For use on a solidly grounded wye
source only.
10) Depending on switching frequency which was set in parameter
P‑0‑0001
Tab. 2-6: UL ratings and dimensions
UL ratings and dimensions (XMQ*)
Description Symbol Unit XMQ*-WQ001 XMQ*-WQ002
Listing in accordance with UL
standard
UL 61800-5-1
Listing in accordance with CSA
standard
C22.2 No. 274-17
UL‑Files E134201
Pollution degree 2
Ambient temperature range with
nominal data
T
amax
°C 40
Mass m kg 10 15
Device height
1)
H mm 309
Device depth
2)
T mm 196.5
Device width
3)
B mm 200 325
14/43
Ratings and dimensions
ctrlX DRIVE Drive Controllers, Supply Units
Bosch Rexroth AG R911392530_Edition 02