Description Symbol Unit
XMS*-
W0054
XMS*-
W0070
XMS*-
W0090
XMS*-
W0100
XMS*-
W0120
XMS*-
W0210
XMS*-
W0250
XMS*-
W0280
Output current
I
out
A AC 27 AC 35 AC 45 AC 67 AC 71
AC
140
AC
147
AC
165
Output frequency range
11)
f
out
Hz 0 ... 1600
1) 2) 3) Housing dimensions
4) 5) 6) See fig. "Air intake and air outlet at device"
7) Comply with supply voltage for motor holding brake;
The following power supply unit has to be used in the scope of
CSA/UL: ● UL508-certified ● output voltage: DC 24V ● output
current: ≤ 31 A; for power supply units with output current >
31 A: install fuses in accordance with UL248
8) See information on "Rated power consumption control voltage
input at U
N3
"
9) Mains input L1, L2, L3; For use on a solidly grounded wye
source only.
10) Copper wire; PVC-insulation (conductor temperature 75 °C;
T
a
≤ 40 °C) in accordance with NFPA 79 chapter 12 and
UL 508A chapter 28
11) Depending on switching frequency which was set in parameter
P‑0‑0001
Tab. 2-5: UL ratings and dimensions
UL ratings and dimensions (XMD*)
Description Symbol Unit
XMD*-
W0606
XMD*-
W1010
XMD*-
W1616
XMD*-
W2323
XMD*-
W5454
XMD*-
W7070
Listing in accordance with UL
standard
UL 61800-5-1
Listing in accordance with CSA
standard
C22.2 No. 274-17
UL‑Files E134201
Pollution degree 2
Ambient temperature range with
nominal data
T
amax
°C 40
Mass m kg 3.3 6.7
Device height
1)
H mm 309
Device depth
2)
T mm 196.5
Device width
3)
B mm 50 150
Minimum distance on the top of
the device
4)
d
top
mm 80
Minimum distance on the bottom
of the device
5)
d
bot
mm 80
Horizontal spacing at the device
6)
d
hor
mm
0 (for devices of the ctrlX DRIVE product group in the DC bus
group (central supply))
1.5 (for devices of the ctrlX DRIVE product group outside of the
DC bus group (individual supply))
10 (for everything else (control cabinet wall, other devices, etc.))
ctrlX DRIVE Drive Controllers, Supply Units 13/43
Ratings and dimensions
R911392530_Edition 02 Bosch Rexroth AG