ctrlX SAFETY "SafeMotion"
Transition functions
Bosch Rexroth AG
R911404905,
Edition 02
Safety technology opera-
tion mode transition
Parameterization Reaction
active
Safety function
selected
Safety function
P‑0‑3280.0.1
P‑0‑3263.0.1
Monitoring
Error message when
SMD monitoring is violated
Bit 3
Bit 8
F3 reaction
(bit 3‑0)
F7 reaction
(bit 7‑4)
When time monitoring
is triggered
When velocity is vio-
lated
1
0 0
SMD with time-based
trend monitoring
F8350 F8351
1 1 F8350 F8351
2 0 or 4
F7050 F7051
4
0
4 F8350 F8351
SMMx
NO
x x x x
-
(no transition necessary, switching takes place directly)
SMMx
SMMx
-
[transitions to SMMx cannot be performed in a drive-controlled way,
they are always NC-controlled (see table "Monitoring functions during
NC-controlled safety technology operation mode transitions")]
Legend:
NO:
Normal operation, safety functions for normal operation
SMMx:
Motion modes (SMM1 – SMM16), safety functions for motion monitoring
x:
not relevant
1):
When configuring P‑0‑3280.0.1, bit 7=0 or P‑0‑3238 > (2 × P‑0‑3255) → F7051 after exceeding P‑0‑3238; when config-
uring P‑0‑3280.0.1, bit 7=1 and P‑0‑3238 ≤ (2 × P‑0‑3255) → Warning E3151 after exceeding P‑0‑3238 with monitoring of
incorrect distance
Safety functions