EasyManua.ls Logo

Bosch rexroth ctrlX SAFETY SafeMotion - Page 259

Bosch rexroth ctrlX SAFETY SafeMotion
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ctrlX SAFETY "SafeMotion"
Motor connections
Bosch Rexroth AG
R911404905,
Edition 02
Motor power supply
Monitoring the motor temperature
Controlling the motor holding brake
Table 35: Motor power supply
View Identification Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
For equipment grounding connection at
motor
Spring terminal (connector) Unit min. max.
Connection cables
Stranded wire
mm
2
0.5 10.0
AWG 24 8
Stripped length mm 12
Occurring current load and minimum
required connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Includes short circuit protection A1, A2, A3 against each other and each of
them against ground
Table 36: Shield connection
Motor cable shield connection
Project planning

Table of Contents

Related product manuals