Thread Mounting torque
M2,5 0.4 Nm
M3 0.7 Nm
M4 1.4 Nm
M5 2.8 Nm
Tab. 14-1: Tightening torques
Ensure that the IP degree of protection of the device is kept during
maintenance.
Include the following tasks into the maintenance schedule:
● Check all plug and terminal connections of the components for proper
tightness and possible damage at least annually. Check that cables are not
broken or crushed. Replace damaged parts immediately
● Check the fan regarding soiling and increased running noise at least annually
Function compatibility for spare parts is ensured for at least ten
years.
14.1 Hard disks
The standard hard disk is mounted on a carrier plate that can be pulled out from
the housing after removing the cover. The hard disk can be replaced, including
the installation frame.
Damages to the device due to electrostatic
discharges!
Comply with all ESD protective measures while working with modules and
components! Avoid electrostatic discharges!
To avoid data loss and new installation of the operating system and
application programs, backup hard disk data regularly.
The new hard disk, including the installation frame, is provided upon
delivery. The new hard disk is always installed with the installation
frame.
To exchange a hard disk, proceed as follows:
1. Store all required user data as well as the operating system settings of your
system either on an external storage medium or via the network
connection!
46/57
Maintenance
IndraControl VPB 40.4
Bosch Rexroth AG R911376309_Edition 02