3 Ratings and Dimensions
UL Ratings and Dimensions
Description Symbol Unit HMD01.1N-W0012 HMD01.1N-W0020 HMD01.1N-W0036
Listing according to UL standard
(UL)
UL 508 C
Listing according to CSA standard
(UL)
Canadian National Standard(s) C22.2 No. 14-10
UL files (UL) E 134201
Pollution degree (UL) 2
Ambient temperature with nominal
data (UL)
T
amax
°C 40
Ambient temperature with reduced
nominal data (UL)
T
amax_red
°C 55
Mass m kg 5,50 5,60 7,50
Device height (UL)
1)
H mm 440
Device depth (UL)
2)
T mm 262
Device width (UL)
3)
B mm 50 75
Minimum distance on the top of
the device
4)
d
top
mm 80
Horizontal spacing on the device
5)
d
hor
mm 0
Minimum distance on the bottom
of the device
6)
d
bot
mm 100
Rated control voltage input (UL)
7)
U
N3
V 24 ± 20 %
Rated power consumption control
voltage input at U
N3
(UL)
8)
P
N3
W 17 11
Short circuit current rating (UL) SCCR A rms 42000
Rated input voltage, power (UL)
9)
U
LN_nenn
V DC 254...750
Rated input current (UL)
I
LN
A 17,0 24,5 49,0
Output voltage (UL)
U
out
V 3 x AC 0...530
Output current (UL)
I
out
A 6,9 10,0 20,0
Field wiring material (material;
conductor temperature; class)
Cu; 60/75 °C; 1
Output frequency range (UL)
10)
f
out
Hz 0...800
Power dissipation at continuous
current
and continuous DC bus
power respectively (UL)
11)
P
Diss_cont
W 2 x 95 2 x 135 2 x 205
Last modification: 2011-05-11
1) 2) 3) Housing dimension; see also related dimensional drawing
4) 5) 6)
See fig. "Air Intake and Air Outlet at Device"
7) Observe supply voltage for motor holding brakes
DOK-INDRV*-HMD01******-IT01-EN-P
Rexroth IndraDrive Drive Controllers Power Sections HMD01
Bosch Rexroth AG 23/67
Ratings and Dimensions
Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com