EasyManua.ls Logo

Bosch Rexroth Rho 4.0 - 3.1.1 Outline structure

Bosch Rexroth Rho 4.0
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2−6 Electric Drives
and Controls
Bosch Rexroth AG RhoMotion 1070072365 / 04
System Overview
2.3 Specifications
Technical data
housing Design as drive module or 19” mo-
dule
44 mm high, aerated
location D vertically near a drive module
D horizontally in the 19” cabinet
Pentium-Prozessor
with Intel MMXT
Technologie
266-, resp. 400-MHz Pentium with
MMX
Second Level Cache 512 K L2 Cache
DRAM 64 MB DIMM- SOII
SRAM max. 4MB SRAM buffered
(central through battery)
Harddisk 64 MB IDE Compact-Flash card
(can be internally plugged)
V24_1/X31
V24_2/X32
ESD solid up to 15 KV
EMV-steadiness meets all requirements set, see
chapter 1.1
power consumption from 24V
current consumption from 24V
approx. 48 W
approx. 2 A
Buffer centrally buffered through battery
Battery monitoring
Battery change every 3 years
CAN-interfaces 2 or 3 (only rho4.0 L)
LAN-interface 10/100 Mbit, RJ45 (Twisted Pair)
. Cables of class 5 at least
must be used
16 digital inputs X21, X22, 8-pin
3,5 mm Weidmüller terminal strip
8 digital outputs X11, 8-pin
3,5 mm Weidmüller terminal strip
Status-LEDs 8, to display the most important
operations states
V24_3/X33 (V24/20 mA-interface) 9-pol. D-SUB, not separated galva-
nically
Sercos-interface In/Out
Floppy-interface 25-pin D-Sub for external floppy
PHG-interface 14-pin safety terminal
25-pin D-Sub für PHG2000 con-
nection

Other manuals for Bosch Rexroth Rho 4.0