2−6 Electric Drives
and Controls
Bosch Rexroth AG RhoMotion 1070072365 / 04
System Overview
2.3 Specifications
Technical data
housing Design as drive module or 19” mo-
dule
44 mm high, aerated
location D vertically near a drive module
D horizontally in the 19” cabinet
Pentium-Prozessor
with Intel MMXT
Technologie
266-, resp. 400-MHz Pentium with
MMX
Second Level Cache 512 K L2 Cache
DRAM 64 MB DIMM- SOII
SRAM max. 4MB SRAM buffered
(central through battery)
Harddisk 64 MB IDE Compact-Flash card
(can be internally plugged)
V24_1/X31
V24_2/X32
ESD solid up to 15 KV
EMV-steadiness meets all requirements set, see
chapter 1.1
power consumption from 24V
current consumption from 24V
approx. 48 W
approx. 2 A
Buffer centrally buffered through battery
Battery monitoring
Battery change every 3 years
CAN-interfaces 2 or 3 (only rho4.0 L)
LAN-interface 10/100 Mbit, RJ45 (Twisted Pair)
. Cables of class 5 at least
must be used
16 digital inputs X21, X22, 8-pin
3,5 mm Weidmüller terminal strip
8 digital outputs X11, 8-pin
3,5 mm Weidmüller terminal strip
Status-LEDs 8, to display the most important
operations states
V24_3/X33 (V24/20 mA-interface) 9-pol. D-SUB, not separated galva-
nically
Sercos-interface In/Out
Floppy-interface 25-pin D-Sub for external floppy
PHG-interface 14-pin safety terminal
25-pin D-Sub für PHG2000 con-
nection