Electric Drives
and Controls
5−3Bosch Rexroth AGRhoMotion1070072365 / 04
Interface Ports & Connectors
5.2 V24_1/X33 through V24_3/X33 serial PC ports
5.2.1 Pin assignment
CAUTION
Functional failures caused by poor shielding!
Use only metallic or conductive connector/coupling shells
providing large-area shield contact.
V24_1/X31, V24_2/X32 Serial interfaces, freely available
D-Sub connector, 9-pin
Type: RS232 compatible
Length of line: maximal 15 m
Type of line: shielded, cross section min. 0.14 mm
2
Rate of transmission 38,4 kBaud
Handshake: Hardware and software handshake
(XON/XOFF)
ESD protection: 15 kV
to the peripheral
equipment
1
2
3
DCD
RXD
TXD
4
X31, X32
Shield via metallic housing of the
plug connection
5
Signal GND
6
7
8
9
RI
DTR
DSR
RTS
CTS
RS232
1
5
69
Assignement as RS-232:
DCD Data Carrier Detect; receiving line, on which for in-
stance a connected device informs the rho4.0 that it
is receiving a carrier signal (existing connection).
RXD Receive Data; Data receiving line
TXD Transmit Data; Data transmitting line to the
peripheral equipment
DTR Data Terminal Ready; transmitting line, on which the
rho4.0 informs a connected peripheral device that
its interface is switched on and initialized.