EasyManua.ls Logo

Bosch Solution 16plus - Dialler Reporting; Transmission Formats, Routes, and Delays

Bosch Solution 16plus
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution 16
plus
20
Bosch Security Systems 09/06 BLCC100R
Quick Start Guide
Areas > Properties >
Input Options MENU 2-1-2
1 Non Sequential Handover (Entry Path) Y
2 Pulse Count Handover Allowed Y
3 Senior Watch N
4 Reset Smoke On Arming Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Output Options MENU 2-1-3
1 Arm/Disarm Speaker Beeps Via RF Keyfob Y
2 Arm/Disarm Speaker Beeps Via Keyswitch Y
3 Siren / Strobe When Part On Allowed Y
4 Alarm On PIN Retry Violations Y
5 Alarm On Exit Error N
6 Alarm On Keyswitch Tamper ( Only If System Armed) Y
7 Reserved N
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Reporting Options MENU 2-1-4
1 Report PIN Retry Y
2 Report Exit Error Y
3 Smart Lockout N
4 Reserved N
5 Cancel Reports Y
6 Reserved N
7 Open / Close Reports For Part On N
8 Open / Close Reports Only After Alarm N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Strobe Trigger MENU 2-1-5
1 Audible Burglary Alarm Y
2 Silent Burglary Alarm N
3 Fire Alarm Y
4 Arm / Disarm Flash Via RF Keyfob N
5
Arm / Disarm Flash Via Keyswitch or PGM Input
N
6 Reserved N
7 24-Hour Alarm Y
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Reporting >
Account Dest 1
MENU 2-2-0
0 0 0 0 0 0 0 0 0 0
Program The Area Account Number For Destination 1 Here (Enter digits
0 – 9 + [OK] To Save
Areas > Reporting >
Account Dest 2
MENU 2-2-1
0 0 0 0 0 0 0 0 0 0
Program The Area Account Number For Destination 2 Here.
Areas > Reporting >
Open / Close Route
MENU 2-2-2
0 = Report Events To Log Only
1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails +Log
Use Keys [] and [] keys or enter 0 - 4 + [OK] To Program Which
Destination ‘Open’ and ‘Close’ Reports Are Sent To.
Areas > Area Testing >
Area Watch
MENU 2-9-0
0 1 2
(*** System Wide Parameter ***)
WEEKS
Enter 0 – 255 + [OK] To Program The Number Of Weeks Before
Register Inactivity Event.
Areas > Area Testing >
User Test Interval
MENU 2-9-1
0 0 0
(*** System Wide Parameter ***)
DAYS
Enter 0 – 255 + [OK] To Program The Number Of Days Before A User
Test Is Requested.
Areas > Area Testing >
Service Interval
MENU 2-9-2
0 0 0
(*** System Wide Parameter ***)
WEEKS
Enter 0 – 255 + [OK] To Program The Number Of Weeks Between
Installer Service Interval.
Areas > Area Testing >
Test Options MENU 2-9-3
1 Monitor User Test Interval Y
2 Reserved N
3 Reserved N
4 Reserved N
5 Reserved N
6 Walk Test Reports Y
7 Walk Test 24-Hour Zones N
8 Walk Test Fire Zones N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.

Table of Contents

Other manuals for Bosch Solution 16plus

Related product manuals