Solution 16
plus
20
Bosch Security Systems 09/06 BLCC100R
Quick Start Guide
Areas > Properties >
Input Options MENU 2-1-2
1 Non Sequential Handover (Entry Path) Y
2 Pulse Count Handover Allowed Y
3 Senior Watch N
4 Reset Smoke On Arming Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Output Options MENU 2-1-3
1 Arm/Disarm Speaker Beeps Via RF Keyfob Y
2 Arm/Disarm Speaker Beeps Via Keyswitch Y
3 Siren / Strobe When Part On Allowed Y
4 Alarm On PIN Retry Violations Y
5 Alarm On Exit Error N
6 Alarm On Keyswitch Tamper ( Only If System Armed) Y
7 Reserved N
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Reporting Options MENU 2-1-4
1 Report PIN Retry Y
2 Report Exit Error Y
3 Smart Lockout N
4 Reserved N
5 Cancel Reports Y
6 Reserved N
7 Open / Close Reports For Part On N
8 Open / Close Reports Only After Alarm N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Properties >
Strobe Trigger MENU 2-1-5
1 Audible Burglary Alarm Y
2 Silent Burglary Alarm N
3 Fire Alarm Y
4 Arm / Disarm Flash Via RF Keyfob N
5
Arm / Disarm Flash Via Keyswitch or PGM Input
N
6 Reserved N
7 24-Hour Alarm Y
8 Reserved N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.
Areas > Reporting >
Account Dest 1
MENU 2-2-0
0 0 0 0 0 0 0 0 0 0
Program The Area Account Number For Destination 1 Here (Enter digits
0 – 9 + [OK] To Save
Areas > Reporting >
Account Dest 2
MENU 2-2-1
0 0 0 0 0 0 0 0 0 0
Program The Area Account Number For Destination 2 Here.
Areas > Reporting >
Open / Close Route
MENU 2-2-2
0 = Report Events To Log Only
1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails +Log
Use Keys [] and [] keys or enter 0 - 4 + [OK] To Program Which
Destination ‘Open’ and ‘Close’ Reports Are Sent To.
Areas > Area Testing >
Area Watch
MENU 2-9-0
0 1 2
(*** System Wide Parameter ***)
WEEKS
Enter 0 – 255 + [OK] To Program The Number Of Weeks Before
Register Inactivity Event.
Areas > Area Testing >
User Test Interval
MENU 2-9-1
0 0 0
(*** System Wide Parameter ***)
DAYS
Enter 0 – 255 + [OK] To Program The Number Of Days Before A User
Test Is Requested.
Areas > Area Testing >
Service Interval
MENU 2-9-2
0 0 0
(*** System Wide Parameter ***)
WEEKS
Enter 0 – 255 + [OK] To Program The Number Of Weeks Between
Installer Service Interval.
Areas > Area Testing >
Test Options MENU 2-9-3
1 Monitor User Test Interval Y
2 Reserved N
3 Reserved N
4 Reserved N
5 Reserved N
6 Walk Test Reports Y
7 Walk Test 24-Hour Zones N
8 Walk Test Fire Zones N
Use Keys [] and [] to scroll up and down the option list. With option
selected press ON / OFF key to enable or disable option. [] will display
to indicate option set. Press [OK] To Save when finished.

Table of Contents

Other manuals for Bosch Solution 16plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16plus and is the answer not in the manual?

Bosch Solution 16plus Specifications

General IconGeneral
BrandBosch
ModelSolution 16plus
CategorySecurity System
LanguageEnglish

Related product manuals