15 | Error Memory
92/136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport
The memory is situated inside the device and is non‐volatile. As a consequence, an error
which has occurred and has not been cleared by the user will remain in the error memory
even after a power cycle. The error state will then reflect if the error is still active or not.
An error is deleted from the list when
the user actively clears the error memory
the user updates the firmware
The error memory is not cleared by a configuration download and is not cleared by a
power cycle.
15.1.2 Clearing the error memory
There are two ways of clearing the error memory, both are shown in the following illustra-
tion: