16 | Lap Trigger
108/136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport
Trigger prohibited
Main Trigger
16.3.3 Distance based forced trigger
After a missed main trigger, a forced trigger is inserted, if the configured max. distance
(i.e. 120 % → 4800m) of the track distance (i.e. 4000m) has been reached. In this case, the
channel ‘Laptrigger_distlap_dls’ starts at the delta between the max. distance and the track
distance (i.e. 800m).
To deactivate distance based forced triggers, uncheck box.
Change signal for vehicle speed,
if desired.
Enter minimum speed for
trigger release.
Define settings for distance
based retrigger protection.
Define settings for distance
based forced trigger.
16.4 Segment timing
Segment timing is the calculation of elapsed time for parts of laps (segments).
Segments are defined:
based on sub-trigger signals (additional transmitters)
based on distance travelled
Times for segments are compared to:
Last lap completed