EasyManua.ls Logo

Bosch VCU - Information on Errors; Error Memory Properties

Bosch VCU
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Memory | 15
Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 93/136
15.2 Information on errors available from the
error memory
In general, properties of the error memory and properties of an individual error need to
be distinguished.
15.2.1 Error Memory Properties
The following property is available for the error memory itself:
Error Status (device measurement label “error_state”)
0: no error present in memory
1: at least one inactive error present in memory, no active errors
2: at least one active error present in memory
If displayed in a measurement sheet, this property’s value (0, 1 or 2) is translated into a
verbal description:

Table of Contents

Related product manuals