11 | Analog and Frequency Inputs
64/136 Vehicle_Control_Unit_VCU_Manual Bosch Motorsport
11.3 Configuring computed sources
Computed sources receive data from a measurement channel rather than an input pin.
– Sensitivity/Offset calculation on input channel
– Characteristic curve calculation on input channel
– Computed vehicle speed
– Lap trigger (covered in a special separate section)
Example: Sensitivity/offset calculation on input channel
1. Click ‘Measurement Sources’ in the Toolbox.
2. Drag the ‘Sensitivity/Offset’ computed source from the Toolbox and drop it on ‘Com-
puted Channels’ in the Vehicle Control Unit VCU Project Tree.
A ‘Computed Sensitivity/Offset Wizard’ opens.
Choose input channel
Choose unit group and
unit of output
Enter sensivity and offset
of conversion formula
3. Click ‘Next’ when done.
The second part of the ‘Computed Sensitivity/Offset Wizard’ opens.