EasyManua.ls Logo

Bosch VCU - Online Calibration of Multipoint Adjustment Channels

Bosch VCU
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Online Measurement and Calibration | 13
Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 77/136
13.3 Online calibration of multipoint adjustment
channels
Example: measurement of wheel force
Physical property ‘wheel force’ not directly measureable
Load transfer through suspension kinematics
Physical value at sensor position defined by vehicle
Curve definition by online adjustment at vehicle
Force at wheel
Force at sensor
1. Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter ‘Configuring a multipoint adjustment [}57]’.
2. Download the configuration on the Vehicle Control Unit VCU. To connect the Vehicle
Control Unit VCU to RaceCon, see chapter ‘Setting up a new RaceCon Project’.
3. Click on the desired channel in the Vehicle Control Unit VCU Project Tree.
4. Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in data
view
Double-click
to open
online view
Click to open
calibration
window
Analog and physical
value
5. Click on ‘Calibrate adjustment points’ to open calibration window.
6. Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
7. Enter the physical value in the value column of the desired calibration point
(e.g.745N).

Table of Contents

Related product manuals