EasyManua.ls Logo

Bosch VCU - Page 57

Bosch VCU
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Analog and Frequency Inputs | 11
Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 57/136
Measurement label Function
raw_name mV value of sensor
raw_name_fi filtered mV value of sensor
name physical value of sensor
name_fi filtered physical value
NOTICE
Working with automatically created measurement sheets is ex-
plained in chapter ‘Setting up an online measurement [
}
70]’.
11.2.4 Configuring a multipoint adjustment
Example: Measurement of wheel force
Physical property ‘wheel force’ not directly measureable
Load transfer through suspension kinematics
Physical value at sensor position defined by vehicle
Curve definition by online adjustment at vehicle
1. Click on ‘Measurement Sources’ in the Toolbox.
2. Expand the list of ‘I/O Channels’ by clicking on ‘+’ in the Vehicle Control Unit VCU
Project Tree.
3. Drag the ‘Multipoint Adjustment’ analog signal source from the Toolbox and drop it
on the desired analog input channel in Vehicle Control Unit VCU Project Tree.

Table of Contents