EasyManua.ls Logo

Bosch VCU - Analog and Frequency Inputs; Analog Inputs

Bosch VCU
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Analog and Frequency Inputs | 11
Bosch Motorsport Vehicle_Control_Unit_VCU_Manual 49/136
11 Analog and Frequency Inputs
Analog inputs
0 to 5 V
12 bit A/D converter
Switchable 3.01 kOhm pull-up resistor
10 kHz acquisition rate, up to 1 kHz recording rate
Linear phase digital filter
Frequency inputs
5 V Hall-effect type, 2.5 V trigger level (DF11 input with current interface or 5VHall-
effect input with 2.5 V trigger level)
20 kHz max. frequency
10 ms measurement window
11.1 Analog inputs
11.1.1 Measurements channels
For each analog channel, several ‘subchannels’ are available.
Measurement labels with the characters ‘raw’ show the exact values in mV.
Measurement labels with the characters ‘_fi’ show filtered values.
The word ‘name’ in the table is a placeholder for the channel’s name.
Measurement label Function
raw_name mV value of sensor
raw_name_fi Filtered mV value of sensor
name Physical value of sensor
name_fi Filtered physical value
Filtered channels are routed through digital low pass filters:
Vehicle Control Unit VCU uses A/D converter oversampling and digital filtering to re-
cording rate
Digital filters eliminate ‘out-of-band’ noise
Cut-off frequency automatically adjusted to recording rate
Linear phase – no signal distortion
Latency compensation – no filter delay in recorded data

Table of Contents

Related product manuals