AUTODOME IP starlight 7000 HD Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en 25
Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679
Figure7.3: Alarm and relay connectors
1 4-pin Alarm
Connector (P102)
2 6-pin Alarm In
Connector (P103)
3 7-pin Relay Connector (P104)
Pin Description Pin Description Pin Description
1 Alarm Out 1 1 Alarm in 3 1 Alarm Out 4 Normally Open
2 Alarm Out 2 2 Alarm in 4 2 Alarm Out 4 COM
3 Alarm Out 3 3 Alarm in 5 3 Alarm Out 4 Normally Closed
4 Alarm Ground 4 Alarm in 6 4 Earth Ground
5 Alarm in 7 5 Analog Alarm 1
6 Alarm Ground 6 Analog Alarm 2
7 Ground
For in-ceiling mount only: Low Voltage TTL (3.3V) can also be used.
4 If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay
Connector to the appropriate incoming wires. Refer to Make Connections in the Power
Supply Box, page 32 for additional information.